Calculator overview
Inputs and outputs
This summary comes from the calculator's published input and output contract.
Inputs
- A07 Old Manual SEER (required) Conditional
-
Unit Btu/Wh Default 13 Range 6 to 40
About this input
The SEER or SEER2 on the nameplate or the AHRI certificate.
- A07 Old Remaining Life
-
When omitted Blank
Unit years Default Not set Range 0 to 30
About this input
Fills the replace-at-end-of-life comparison. Blank skips it.
- A07 Old Sale Value
-
When omitted Blank
Unit $ Default Not set Range 0 to 5000
About this input
Money you receive for the old unit if you replace it now.
- A07 Old Cooling KWh (required) Conditional
-
Unit kWh/yr Default 3000 Range 0 to 50000
About this input
The extra electricity your summer bills show for cooling in a year (above 0). The load is this figure x the old unit's SEER2-equivalent / 1000.
- A07 Old Maintenance
-
When omitted Blank
Unit $/yr Default Not set Range 0 to 5000
About this input
Service or repairs you expect each year if you keep the old unit.
- A07 Old Manual Rating Basis (required) Conditional
-
Default SEER (rated before 2023) Allowed SEER2 (rated 2023 or later), SEER (rated before 2023), Unknown
About this input
SEER2 (rated 2023 or later), SEER (rated before 2023) or Unknown. A SEER figure is put on the SEER2 basis with DOE's factor for its class; an unknown basis is used as if it were SEER2, which understates the savings, and the status says so. Left blank, it counts as Unknown.
- A07 Old Source (required)
-
Default Manual entry (nameplate or AHRI certificate) Allowed Model not found: pick approximate age, Manual entry (nameplate or AHRI certificate)
About this input
Type its SEER from the nameplate or the AHRI certificate, or give the year it was made (the federal minimum for its type, region and year is used). There is no central AC model list.
- A07 Sales Tax Rate
-
When omitted Blank
Default Not set Range 0 to 0.15
About this input
Applied to the installed price only.
- A07 State (required)
-
Default US Allowed AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, IA, ID, IL, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WI, WV, WY, US
About this input
USPS state code, or US for the national average. It sets the default electricity price (a state average, not your tariff), the cooling degree days for the estimate, and the DOE region of the federal minimums.
- A07 System Size Tons (required)
-
Unit tons Default 3 Range 0.5 to 6
About this input
The nominal cooling size, in tons (12,000 Btu/h each), from the nameplate (for example 36 in the model number means 3 tons). It sets the estimated cooling load.
- A07 Old Type (required)
-
Default Split system Allowed Split system, Single package
About this input
Split system (outdoor unit and indoor coil) or single package (one cabinet). It sets the federal class.
- A07 Old Vintage (required) Conditional
-
Default Made in 2010 Allowed Made in 1992, Made in 1993, Made in 1994, Made in 1995, Made in 1996, Made in 1997, Made in 1998, Made in 1999, Made in 2000, Made in 2001, Made in 2002, Made in 2003, Made in 2004, Made in 2005, Made in 2006, Made in 2007, Made in 2008, Made in 2009, Made in 2010, Made in 2011, Made in 2012, Made in 2013, Made in 2014, Made in 2015, Made in 2016, Made in 2017, Made in 2018, Made in 2019, Made in 2020, Made in 2021, Made in 2022, Made in 2023, Made in 2024, Made in 2025
About this input
When the rating is not known: the year made. The federal minimum for its type, your state's region and that year is used (SEER before 2023, converted to SEER2; SEER2 from 2023); your unit may be more efficient, so the status says so.
- A07 Rate Growth (required)
-
Default 0.02 Range -0.1 to 0.15
About this input
Applied to the electricity price each year. 0% means flat prices.
- A07 New Type (required)
-
Default Split system Allowed Split system, Single package
About this input
Split system or single package. It sets the federal class of the minimum route.
- A07 Electricity Rate Override
-
When omitted Blank
Unit $/kWh Default Not set Range 0.01 to 2
About this input
From your bill. Overrides the state average.
- A07 Extra Work
-
When omitted Blank
Unit $ Default Not set Range 0 to 50000
About this input
Work beyond the installed price, if your quote lists it separately.
- A07 Horizon Years (required)
-
Unit years Default 15 Range 1 to 30
About this input
The comparison period, 1 to 30 whole years.
- A07 CDD Override
-
When omitted Blank
Unit deg F-day Default Not set Range 0 to 6000
About this input
Your own yearly cooling degree days (base 65 deg F), in place of the state normal. Used only when the load is estimated.
- A07 Discount Rate (required)
-
Default 0.03 Range 0 to 0.2
About this input
The yearly return you could earn on the money instead. 0% means no discounting.
- A07 Disposal
-
When omitted Blank
Unit $ Default Not set Range 0 to 5000
About this input
Removal, refrigerant recovery or recycling charge, if any.
- A07 Incentives
-
When omitted Blank
Unit $ Default Not set Range 0 to 5000
About this input
Only incentives you have confirmed you qualify for.
- A07 New Maintenance
-
When omitted Blank
Unit $/yr Default Not set Range 0 to 5000
About this input
Service you expect each year for the new unit.
- A07 New Manual SEER2 (required) Conditional
-
Unit Btu/Wh Default 16 Range 10 to 40
About this input
The SEER2 on the AHRI certificate of the outdoor unit and coil you are quoted.
- A07 New Source (required)
-
Default Manual entry (AHRI certificate) Allowed Manual entry (AHRI certificate), Federal minimum for my state
About this input
Type its SEER2 from the AHRI certificate of the quoted system, or use the federal minimum for new units in your state's region.
- A07 Load Source (required)
-
Default Estimate from my state and system size Allowed Estimate from my state and system size, From my bills: yearly cooling kWh
About this input
Estimate it from your state's cooling degree days and the system size, or work it out from the cooling electricity on your bills.
- A07 New Expected Life
-
When omitted Blank
Unit years Default Not set Range 1 to 40
About this input
Used only for the value left in the new unit at the end of the period (straight line). Blank counts no value left: no lifetime is sourced for this app.
- A07 New Installed Price (required)
-
Unit $ Default 7000 Range 1 to 50000
About this input
The installed price of the new central AC job, from your contractor's quote. The calculator never looks up a price. Illustrative price for this example, not a quote or a current price. Prices vary: check current prices online or enter your own. Get a contractor quote.
Outputs
- A07 PV Keep
-
Unit $
About this output
Present value of keeping the old unit at the discount rate.
- A07 Old Model Card
-
No unit declared
About this output
Old unit: The unit as the calculator reads it: your nameplate or AHRI figure, or the federal minimum for its type, region and year.
- A07 PV Replace End Of Life
-
Unit $
About this output
Present value of replacing when the old unit fails. Blank when not evaluated.
- A07 Rating Note
-
No unit declared
About this output
Which old rating is used, and whether DOE's SEER-to-SEER2 factor is applied.
- A07 PV Replace Now
-
Unit $
About this output
Present value of replacing now at the discount rate.
- A07 Old Annual Energy Cost
-
Unit $/yr
About this output
Old unit: Electricity cost in year 1.
- A07 Old Annual Cooling KWh
-
Unit kWh/yr
About this output
Old unit: Electricity to remove the house's cooling load: the load x 1000 / efficiency.
- A07 Old Annual KWh
-
Unit kWh/yr
About this output
Old unit: All electricity in the comparison (cooling only).
- A07 Old Eff Cooling Used
-
Unit Btu/Wh
About this output
Old unit: The SEER2 or SEER2-equivalent in the sums: a SEER (rated before 2023) times DOE's factor for its class, a SEER2 as given, or a figure of unknown basis as if it were SEER2.
- A07 Old Annual Total Cost
-
Unit $/yr
About this output
Old unit: Energy cost plus upkeep in year 1.
- A07 Total Keep
-
Unit $
About this output
Running cost of keeping the old unit over the years compared, without discounting.
- A07 Status Code
-
No unit declared
About this output
The deciding reason of the status line as a short code, OK when nothing applies.
- A07 Total Replace End Of Life
-
Unit $
About this output
Keep the old unit until it fails, then buy the new one at today's price. Blank when no remaining life below the period is given.
- Model Status
-
No unit declared
About this output
OK, CHECK with a reason to read, or NOT VALID with what to fix.
- A07 Total Replace Now
-
Unit $
About this output
Net initial cost plus the new unit's running cost over the years compared, less any value left at the end, without discounting.
- A07 Self Check
-
No unit declared
About this output
Whether the model's internal consistency checks hold.
- A07 Replace Now Verdict
-
No unit declared
About this output
The comparison of replacing now with keeping, in words.
- A07 Sensitivity Savings
-
No unit declared
About this output
Money saved in year 1 for 50% to 150% of the cooling load (rows) and 50% to 150% of the electricity price used (columns).
- A07 Simple Payback Years
-
Unit years
About this output
Net initial cost divided by the money saved in year 1. Blank when nothing is saved or the price is missing.
- A07 Simple Payback Text
-
No unit declared
About this output
The simple payback in words: the years, no payback, or a missing price.
- A07 Discounted Payback Text
-
No unit declared
About this output
The discounted payback in words.
- A07 Data Vintage Note
-
No unit declared
About this output
The sources and their dates.
- A07 Discounted Payback Year
-
Unit year
About this output
The first year in which the cumulative discounted net benefit of replacing now reaches zero. Blank when it does not within the years compared.
- A07 Electricity Rate Used
-
Unit $/kWh
About this output
The electricity price in the sums: your own, or the state average.
- A07 Electricity Rate Note
-
No unit declared
About this output
Where the electricity price comes from: the EIA state average and its year, or your own price.
- A07 Annual Savings USD
-
Unit $/yr
About this output
Old minus new running cost in year 1; negative means the new unit costs more to run.
- A07 Annual KWh Change
-
Unit kWh/yr
About this output
Old minus new electricity a year.
- A07 Cash Flow
-
No unit declared
About this output
Year-by-year costs of keeping, replacing now and replacing at end of life, the net benefit of replacing now, and its cumulative and discounted values. Rows past the years compared are blank.
- A07 Cooling Load MMBtu
-
Unit MMBtu/yr
About this output
Heat the house needs removed in a year: estimated from the system size and your state's degree days, or worked out from your bills. Old and new remove the same heat.
- A07 Climate CDD Used
-
Unit deg F-day
About this output
The cooling degree days that scale the estimate (your override or the state normal, NOAA 1991-2020). Blank on the bills route.
- A07 New Annual Total Cost
-
Unit $/yr
About this output
New unit: Energy cost plus upkeep in year 1.
- A07 New Annual KWh
-
Unit kWh/yr
About this output
New unit: All electricity in the comparison (cooling only).
- A07 New Eff Cooling Used
-
Unit Btu/Wh
About this output
New unit: The SEER2 or SEER2-equivalent in the sums: a SEER (rated before 2023) times DOE's factor for its class, a SEER2 as given, or a figure of unknown basis as if it were SEER2.
- A07 NPV Replace Now
-
Unit $
About this output
Present value of keeping minus that of replacing now; positive means replacing now costs less.
- A07 New Model Card
-
No unit declared
About this output
New unit: The unit as the calculator reads it: your nameplate or AHRI figure, or the federal minimum for its type, region and year.
- A07 Load Basis Note
-
No unit declared
About this output
How the cooling load is worked out: estimated from your state and the system size, or from your bills.
- A07 End Of Life Verdict
-
No unit declared
About this output
The comparison of replacing now with waiting until the old unit fails, in words.
- A07 Net Initial Cost
-
Unit $
About this output
Installed price, extra work and sales tax, less incentives, plus removal, less the old unit's sale value.
- A07 New Annual Energy Cost
-
Unit $/yr
About this output
New unit: Electricity cost in year 1.
- A07 New Annual Cooling KWh
-
Unit kWh/yr
About this output
New unit: Electricity to remove the house's cooling load: the load x 1000 / efficiency.
LogicCommons is in beta. If a result, label, or reference looks wrong, tell us here; we read every message.
What it is
This calculator weighs keeping your central air conditioner against replacing it with a new one. Describe the old unit by the year it was made or by the SEER on its nameplate, enter the new unit's SEER2 from its AHRI certificate or compare at the federal minimum, and give your system size and state, or your old unit's yearly electricity from your bills. It works out your cooling need, each unit's yearly electricity and cost, the yearly saving, the net cost of the new system, the simple and discounted payback, and the cost over the years you choose of keeping the old unit, replacing it now, or replacing it when it wears out.
Ratings and climate figures come from federal sources only: DOE efficiency standards and test procedures, NOAA climate normals and EIA electricity prices. Older and newer ratings are never mixed. You set the installed price; the opening example and each worked example carry a round illustrative price, labelled as such.
Methodology
Purpose and model boundary
This calculator compares keeping the central air conditioner you have with replacing it with a new one. It works out the cooling your home needs, from your bills or from your state's climate and your system's size, the electricity each air conditioner needs to deliver it, and the cost at your electricity price, and sets the yearly saving against what the new system costs installed. Over the number of years you choose, it compares keeping the old system, replacing it now and, when you say how many years the old one has left, replacing it when it wears out.
Every figure on this page is computed by the spreadsheet; the page adds nothing to it. It covers cooling running cost and purchase cost only, for the same ducts; a change of distribution system is not modelled.
Inputs and units
- The old air conditioner: split system or single package, described by the year it was made, for which the calculator uses the federal minimum SEER for your state's region, or by its SEER from the nameplate or AHRI certificate (6 to 40) with the basis of that rating: SEER2 (rated 2023 or later), SEER (rated before 2023), or Unknown.
- Your cooling need: the size of your system, 0.5 to 6 tons, and where the need comes from: an estimate from your state and system size, or your old air conditioner's yearly electricity from your bills. Optionally, your own cooling degree days, which replace your state's figure.
- The new air conditioner: split system or single package, with its SEER2 from the AHRI certificate (10 to 40), or compared at the federal minimum for your state.
- Price: the state, which sets the default electricity price, and your own electricity price in dollars per kWh (0.01 to 2.00), optional.
- Purchase and finance: the installed price of the new system, which is always yours to set; extra work such as permits, electrical or duct work; sales tax; verified incentives; removal; the old unit's sale value; yearly upkeep of each unit; the years the old unit has left; the new unit's expected life; the yearly change in electricity prices; the discount rate; and the years to compare.
Heating and cooling needs are in million Btu (MMBtu) a year of heat delivered or removed. Electricity is in kWh, fuel in US gallons or therms, efficiency ratings in Btu per watt-hour (CEER, SEER2, HSPF2) or as a fraction (AFUE), and money in dollars.
Governing relationships
- Estimated need: cooling need = system size (tons x 12,000 Btu/h) x 1,000 cooling hours x your state's cooling degree days / the US figure. The 1,000 hours are DOE's representative cooling use cycle from the 2016 edition of its test-procedure rule; scaling them by your state's degree days is this calculator's own, labelled approximation.
- Need from your bills: your old air conditioner's yearly electricity is turned back into the heat it removed, using its own rating.
- Older and newer ratings are not mixed. A SEER rating from before 2023 is put on the SEER2 basis with the exact ratio of DOE's equivalent standard levels for its product class, from DOE's January 2017 direct final rule (82 FR 1786): 13.4/14 for a split or single-package air conditioner. That ratio translates standard levels, so applying it to one old unit is an approximation, and the rating note says so. With an Unknown basis the old rating is used as it stands, which makes the old unit look more efficient than it is, so the saving is understated.
- Electricity: cooling kWh = cooling need in Btu / (SEER2 x 1000).
- Yearly cost = electricity x electricity price + upkeep; the yearly saving is the old cost minus the new cost. Payback and present value follow the rules shared with the other replacement calculators, with nothing counted twice.
Calculation sequence
The spreadsheet first checks the inputs and finds each air conditioner's rating, the climate figures and the electricity price. It works out the cooling need once, shared by both units, reduces each unit to the electricity it uses per million Btu of cooling, and from those computes the yearly electricity, costs and saving; the purchase cost, the paybacks, the present values and the year-by-year cash flow follow. The sensitivity table uses the same per-MMBtu figures, so it cannot disagree with the main result. Consistency checks, including that your bills are reproduced from the computed need on the bills route and that the discounted cash flow reaches the same net present value as the closed-form formula, run before the status is returned.
Outputs and interpretation
The results show the yearly cooling need, the cooling degree days used, and for each air conditioner the rating used (after any conversion), the yearly electricity, and the yearly energy and total cost; then the yearly saving in dollars and kWh, the net cost of the new system, the simple and discounted payback, and the cost of each path. A note states where the need came from (your state's degree days and DOE use hours, or your bills) and another whether the old rating was converted.
The cash-flow table shows each year of the years compared: the cost of each path, the net benefit of replacing now, and its cumulative, discounted and cumulative discounted values. The sensitivity table shows the yearly saving with the cooling need scaled by 0.50, 0.75, 1.00, 1.25 and 1.50, at the same multiples of the electricity price used.
The first chart, “Cumulative net benefit of replacing now, by year”, shows Undiscounted and Discounted by year. The second chart, “Cost over the years compared”, shows Total and Present value by option. The third chart, “Running cost in year 1”, shows Cooling electricity and Upkeep by unit, stacked.
Validation and status logic
The workbook returns one status, chosen in this order: NOT VALID, then CHECK, then OK.
- NOT VALID names the first problem: an old-unit source or type that is not one of its options; no federal minimum on file for that type, region and year made, in which case use the nameplate rating; a manual SEER missing or outside 6 to 40, or a rating basis that is not one of its options; a system size missing or outside 0.5 to 6 tons; the same problems for the new unit: a federal-minimum choice with no minimum on file, or a manual SEER2 missing or outside 10 to 40; a source of the need that is not one of its options, or a bills figure missing or outside its limits; the estimate needs degree days and your state has no figure and you have not entered your own; no electricity price, or your own outside 0.01 to 2.00 dollars per kWh; a missing installed price, or one outside its limits; a money amount, the years compared, the price change, the discount rate or a life in years outside its limits.
NOT VALIDis a refusal, not a numeric answer: every figure reads zero and is withheld. - CHECK accompanies a computed result that needs the stated review: the old rating is the federal minimum for the year made; the old unit may be more efficient, so the saving may be overstated; an old SEER rating with an Unknown basis, or with no conversion ratio for its class, is used as if it were SEER2, so the saving is probably understated; zero cooling electricity on the bills route; no yearly saving, so there is no payback; the old unit's remaining life is shorter than the years compared, so read the end-of-life comparison.
- OK otherwise.
Assumptions and limitations
- No federal model list and no ENERGY STAR level. The ENERGY STAR certified central air conditioner list held no models when the data were collected, and the current ENERGY STAR specification covers heat pumps only, so there is no ENERGY STAR level for a cooling-only air conditioner. The new unit is described by its SEER2 from the AHRI certificate, or compared at the federal minimum.
- Two labelled approximations. The figures behind them are DOE's, but how this calculator applies them is its own: DOE's standard-level ratio is applied to one old unit's SEER, and DOE's national cooling hours are scaled by your state's degree days. Your bills route avoids the second, and a rating on the SEER2 basis avoids the first.
- Not modelled: adjusting your bills for a mild or hot year, solar and internal heat gains beyond what the degree-day base implies, humidity removal beyond the SEER2 test, and duct changes.
- A federal minimum is a floor, not a measurement. An old unit described by the year it was made may be more efficient than the minimum, so the saving may be overstated. The minimum depends on your state's region; where the minimum changed during a year, the newer, higher minimum is used; and for systems of 45,000 Btu/h and more in the Southeast and Southwest the floor used is slightly higher than theirs. Each of these keeps the saving on the low side. Wear with age is not modelled.
- Alaska, Hawaii and DC. NOAA publishes no statewide degree-day normals for any of the three. DC uses Maryland's figures; Alaska and Hawaii each use one NOAA station normal, at the Anchorage and Honolulu airports, labelled as a single station. Your own degree days replace any state figure, and the bills route works everywhere.
- Prices. The installed price of the new system is always your input; the workbook holds no price table. The opening example and each worked example carry a round illustrative price so that they compute, with the note: "Illustrative price for this example, not a quote or a current price. Prices vary: check current prices online or enter your own. Get a contractor quote."
- The default electricity price is a state average. Your own price from your bill overrides it.
Data and vintage
- Federal minimum ratings by year made and region: DOE energy conservation standards (10 CFR 430.32), with earlier editions of the Code of Federal Regulations (1997 and 2012) for the years before the current standard.
- Rating ratio and use hours: DOE's January 2017 direct final rule (82 FR 1786) for the SEER level ratio, and the 2016 edition of 10 CFR 430.23 for the representative cooling hours.
- Climate: NOAA NCEI statewide cooling degree-day normals for 1991-2020 (nClimDiv); the US figure covers the 48 contiguous states. NOAA calls these long-term averages rather than official normals, and its notes state neither the base temperature nor the weighting.
- Default price: EIA final 2025 average residential electricity prices by state (Form EIA-861).
Worked examples and prices
Prices are not part of the reference data: the price of the new unit is an input you set. The opening example and the five worked examples each use an illustrative price for the new unit, so that the example computes, and each says so: “Illustrative price for this example, not a quote or a current price. Prices vary: check current prices online or enter your own.”
Restrictions and non-computing states
The calculator enforces its numeric and choice limits before it accepts a result. A listed model that is not in its list or does not match the type chosen, a rating or quantity outside its limits, a missing installed price, and a missing electricity or fuel price where no default exists are refused by the workbook.
Errors and warnings
A request rejected by the page's input limits is not a computed result. A transport or service failure, a timeout or a cancelled run cannot establish a fresh workbook answer, and the last result stays on the page marked as out of date. Check your equipment's nameplate or AHRI certificate and your own bills before relying on a result for a purchase, and get a contractor quote for the installed price.
References
Sources and further reading
The calculator reads federal minimum ratings, rating conversion factors, climate figures and default electricity prices from reference tables inside the workbook. This calculator has no model list. Every table comes from a US federal source. The sources below publish the data and the rules the model applies. They do not endorse this calculator.
- DOE energy conservation standards, 10 CFR 430.32 (eCFR) sets the SEER2 minimums for central air conditioners made from 2023, by region, and the SEER minimums before them; earlier editions give the older levels (retrieved 2026-10-28).
- DOE test procedures, 10 CFR 430 subpart B (eCFR) defines SEER2 under appendix M1, which replaced SEER under appendix M for ratings from 2023; 10 CFR 430.23, CFR 2016 edition (govinfo) gives the representative 1,000 cooling hours a year (retrieved 2026-10-28).
- DOE direct final rule, 82 FR 1786, January 6, 2017 (Federal Register), Tables V-29 and V-30, gives the 2023 standard levels under the older and the newer test, whose ratio converts an older SEER (retrieved 2026-10-28).
- ENERGY STAR data portal catalog (EPA) lists the EPA's certified-product datasets; it has no central air conditioner dataset, and the filtered central air conditioner view returned no models (retrieved 2026-10-28).
- ENERGY STAR air-source heat pumps: information for partners (EPA) links the current ENERGY STAR specification, whose criteria cover heat pumps only, with no level for a cooling-only air conditioner (retrieved 2026-10-28).
- NOAA NCEI, Climate Divisional Database (nClimDiv) publishes statewide cooling degree-day normals, used here for 1991-2020 (retrieved 2026-10-28).
- NOAA NCEI, U.S. Climate Normals 1991-2020, station files gives the Anchorage and Honolulu airport normals that stand in for Alaska and Hawaii (retrieved 2026-10-28).
- EIA, Detailed state data (Form EIA-861) gives the average residential electricity price by state, used here for 2025 (retrieved 2026-10-28).
- EIA, Residential Energy Consumption Survey 2020, state data gives typical air-conditioning electricity per household by state for 2020, a cross-check for your own figure; it is not a value in the calculator (retrieved 2026-10-28).
This is an educational estimate of running and purchase costs for the equipment and prices you enter, not a product recommendation or a quote. Ratings are measured under federal test procedures, not in your home.
Frequently asked questions
Why can't I pick a central air conditioner from a list?
What is the difference between SEER and SEER2?
Should I use my bills or the estimate?
Does a bigger new air conditioner use more electricity?
Found a problem, or have an idea?
Tell us if a result looks wrong, a label is unclear, or something is missing. We read every message.