Calculator overview
Inputs and outputs
This summary comes from the calculator's published input and output contract.
Inputs
- H04 New Source (required)
-
Default Model from current ENERGY STAR list Allowed Model from current ENERGY STAR list, Manual entry (AHRI certificate)
About this input
Pick a currently certified ENERGY STAR model by its outdoor unit, or type the HSPF2 from the AHRI certificate your contractor gives you.
- H04 New Type (required)
-
Default Ducted split Allowed Ducted split, Ductless mini/multi-split, Single package
About this input
Ducted split (uses ducts), ductless mini or multi-split, or single package. It chooses which model list is shown.
- H04 Old Heating KWh (required)
-
Unit kWh/yr Default 10000 Range 0 to 100000
About this input
The electricity your baseboards or electric furnace use for heating in a year: your winter bills minus the use of a month without heating, for example. It must be more than 0; it is the baseline the heating load is worked out from.
- H04 New Model Mini (required) Conditional
-
Default 1HVAC | ACIQ-06ZPL-HP230B Allowed 1HVAC | ACIQ-06ZPL-HP230B, 1HVAC | ACIQ-06ZPL-HP230C, 1HVAC | ACIQ-09Z-HP115B, 1HVAC | ACIQ-09Z-HP115C, 1HVAC | ACIQ-09Z-HP230C, 1HVAC | ACIQ-09ZPL-HP230B, 1HVAC | ACIQ-09ZPL-HP230C, 1HVAC | ACIQ-09ZS-HP115C, 1HVAC | ACIQ-09ZS-HP230C, 1HVAC | ACIQ-12ZPL-HP230B, and 7,091 more (the calculator lists them all)
About this input
Brand and outdoor unit model as listed by ENERGY STAR (ductless mini and multi-split). The lowest HSPF2 of its certified combinations is used.
- H04 New Model Pkg (required) Conditional
-
Default 1HVAC | ACIQ-PHH1748000K000V Allowed 1HVAC | ACIQ-PHH1748000K000V, 1HVAC | ACIQ-PHH1760000K000V, AC PRO | AK-H04TC/NAA-T(U), AC PRO | AK-H05TC/NAA-T(U), AC PRO | PKHP-X-024VBC, AC PRO | PKHP-X-036VBC, AC PRO | PKHP-X-048VBC, AC PRO | PKHP-X-060VBC, ACIQ | ACIQ-PHH1748000K000V, ACIQ | ACIQ-PHH1760000K000V, and 820 more (the calculator lists them all)
About this input
Brand and model as listed by ENERGY STAR (single package). The lowest HSPF2 of its certified combinations is used.
- H04 New Model Split (required) Conditional
-
Default Carrier | D5CURAH36AAK Allowed 1HVAC | ACIQ-12-EHPB, 1HVAC | ACIQ-12-EHPD, 1HVAC | ACIQ-18-EHPD, 1HVAC | ACIQ-18-HPB, 1HVAC | ACIQ-18-HPD, 1HVAC | ACIQ-18ZPL-HP230B, 1HVAC | ACIQ-24-EHPB, 1HVAC | ACIQ-24-EHPD, 1HVAC | ACIQ-24-HP32, 1HVAC | ACIQ-24-HPB, and 4,581 more (the calculator lists them all)
About this input
Brand and outdoor unit model as listed by ENERGY STAR. The lowest HSPF2 of its certified combinations is used.
- H04 Rate Growth (required)
-
Default 0.02 Range -0.1 to 0.15
About this input
Applied to electricity and gas prices alike. 0% means flat prices.
- H04 Sales Tax Rate
-
When omitted Blank
Default Not set Range 0 to 0.15
About this input
Applied to the installed price only.
- H04 State (required)
-
Default US Allowed AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, IA, ID, IL, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WI, WV, WY, US
About this input
USPS state code, or US for the national average. It sets the default electricity price (a state average, not your tariff) and the climate used by the two climate checks.
- H04 Old Maintenance
-
When omitted Blank
Unit $/yr Default Not set Range 0 to 5000
About this input
Service or repairs you expect each year if you keep the resistance heat.
- H04 Old Remaining Life
-
When omitted Blank
Unit years Default Not set Range 0 to 30
About this input
Fills the replace-at-end-of-life comparison. Blank skips it.
- H04 Old Sale Value
-
When omitted Blank
Unit $ Default Not set Range 0 to 5000
About this input
Money you receive for the old system if you replace it now.
- H04 New Manual HSPF2 (required) Conditional
-
Unit Btu/Wh Default 8 Range 5 to 20
About this input
The heating seasonal performance factor (HSPF2, 2023 test basis) of the matched system. Never an older HSPF figure.
- H04 Disposal
-
When omitted Blank
Unit $ Default Not set Range 0 to 5000
About this input
Removal or capping charge, if not in the quote.
- H04 Electricity Rate Override
-
When omitted Blank
Unit $/kWh Default Not set Range 0.01 to 2
About this input
From your bill. Overrides the state average.
- H04 Extra Work
-
When omitted Blank
Unit $ Default Not set Range 0 to 50000
About this input
Work beyond the installed price, if your quote lists it separately.
- H04 Backup Share (required) Conditional
-
Default 0.1 Range 0 to 1
About this input
The extra share of the yearly heat the backup supplies. Read only when a backup is chosen.
- H04 Backup Type (required)
-
Default None beyond the rating Allowed None beyond the rating, Electric resistance (keep the baseboards)
About this input
HSPF2 already includes the backup heat of a moderate climate. Choose a backup only for extra heat in a colder climate: keeping your baseboards (electric resistance).
- H04 Discount Rate (required)
-
Default 0.03 Range 0 to 0.2
About this input
The yearly return you could earn on the money instead. 0% means no discounting.
- H04 New Expected Life
-
When omitted Blank
Unit years Default Not set Range 1 to 40
About this input
Used only for the value left in the heat pump at the end of the period (straight line). Blank counts no value left: no lifetime is sourced for this app.
- H04 New Installed Price (required)
-
Unit $ Default 12000 Range 1 to 60000
About this input
The installed price of the heat pump job, from your contractor's quote. The calculator never looks up a price. Illustrative price for this example, not a quote or a current price. Prices vary: check current prices online or enter your own. Get a contractor quote.
- H04 New Maintenance
-
When omitted Blank
Unit $/yr Default Not set Range 0 to 5000
About this input
Service you expect each year for the heat pump.
- H04 Horizon Years (required)
-
Unit years Default 15 Range 1 to 30
About this input
The comparison period, 1 to 30 whole years.
- H04 HP Seasonal COP Override
-
When omitted Blank
Unit W/W Default Not set Range 1 to 6
About this input
A seasonal coefficient of performance for your climate, if your contractor states one. It replaces the HSPF2 rating, which assumes a moderate climate.
- H04 Incentives
-
When omitted Blank
Unit $ Default Not set Range 0 to 5000
About this input
Only incentives you have confirmed you qualify for.
Outputs
- H04 Old Seasonal COP Used
-
Unit W/W
About this output
Old resistance heat: The seasonal coefficient of performance in the sums: 1.0 for resistance heat; for the heat pump your COP, or HSPF2 x 1000 / 3,412.
- H04 Old Model Card
-
No unit declared
About this output
Old resistance heat: The system as the calculator reads it: the resistance heat's yearly kWh, or the heat pump's model, HSPF2, capacities and record.
- H04 PV Keep
-
Unit $
About this output
Present value of keeping the resistance heat at the discount rate.
- H04 PV Replace Now
-
Unit $
About this output
Present value of replacing now at the discount rate.
- H04 PV Replace End Of Life
-
Unit $
About this output
Present value of replacing when the resistance heat fails. Blank when not evaluated.
- H04 Old Annual Heating KWh
-
Unit kWh/yr
About this output
Old resistance heat: Electricity used to heat: the resistance heat, or the heat pump and any electric backup.
- H04 Old Annual Energy Cost
-
Unit $/yr
About this output
Old resistance heat: Electricity cost in year 1.
- H04 Old Annual KWh
-
Unit kWh/yr
About this output
Old resistance heat: All electricity in the comparison (heating only in this app).
- H04 Old Eff Heating Used
-
Unit Btu/Wh
About this output
Old resistance heat: The heat pump's HSPF2: the lowest certified combination, your AHRI figure, or your seasonal COP as an HSPF2 equivalent. Blank for resistance heat.
- H04 Old Annual Total Cost
-
Unit $/yr
About this output
Old resistance heat: Energy cost plus upkeep in year 1.
- H04 Rating Note
-
No unit declared
About this output
Which heat pump rating is used: the lowest certified combination, your AHRI figure, or your seasonal COP.
- H04 Total Keep
-
Unit $
About this output
Running cost of keeping the resistance heat over the years compared, without discounting.
- H04 Status Code
-
No unit declared
About this output
The deciding reason of the status line as a short code, OK when nothing applies.
- H04 Total Replace End Of Life
-
Unit $
About this output
Keep the resistance heat until it fails, then install the heat pump at today's price. Blank when no remaining life below the period is given.
- Model Status
-
No unit declared
About this output
OK, CHECK with a reason to read, or NOT VALID with what to fix.
- H04 Total Replace Now
-
Unit $
About this output
Net initial cost plus the heat pump's running cost over the years compared, less any value left at the end, without discounting.
- H04 Self Check
-
No unit declared
About this output
Whether the model's internal consistency checks hold.
- H04 Replace Now Verdict
-
No unit declared
About this output
The comparison of replacing now with keeping, in words.
- H04 Sensitivity Savings
-
No unit declared
About this output
Money saved in year 1 for 50% to 150% of the heating load (rows) and 50% to 150% of the electricity price used (columns).
- H04 Simple Payback Years
-
Unit years
About this output
Net initial cost divided by the money saved in year 1. Blank when nothing is saved or the price is missing.
- H04 Simple Payback Text
-
No unit declared
About this output
The simple payback in words: the years, no payback, or a missing price.
- H04 Discounted Payback Year
-
Unit year
About this output
The first year in which the cumulative discounted net benefit of replacing now reaches zero. Blank when it does not within the years compared.
- H04 Discounted Payback Text
-
No unit declared
About this output
The discounted payback in words.
- H04 Electricity Rate Note
-
No unit declared
About this output
Where the electricity price comes from: the EIA state average and its year, or your own price.
- H04 End Of Life Verdict
-
No unit declared
About this output
The comparison of replacing now with waiting until the resistance heat fails, in words.
- H04 Electricity Rate Used
-
Unit $/kWh
About this output
The electricity price in the sums: your own, or the state average.
- H04 Annual Savings USD
-
Unit $/yr
About this output
Old minus new running cost in year 1; negative means the heat pump costs more to run.
- H04 Annual KWh Change
-
Unit kWh/yr
About this output
Old minus new electricity a year: the electricity the heat pump saves.
- H04 Cash Flow
-
No unit declared
About this output
Year-by-year costs of keeping, replacing now and replacing at end of life, the net benefit of replacing now, and its cumulative and discounted values. Rows past the years compared are blank.
- H04 Data Vintage Note
-
No unit declared
About this output
The sources and their dates.
- H04 Climate HDD Used
-
Unit deg F-day
About this output
Your state's yearly heating degree day normal (NOAA 1991-2020), used only by the two climate checks.
- H04 Heating Load MMBtu
-
Unit MMBtu/yr
About this output
Heat the home needs in a year, worked out from your heating kWh (resistance heat delivers all its electricity as heat). Old and new deliver the same heat.
- H04 New Eff Heating Used
-
Unit Btu/Wh
About this output
Heat pump: The heat pump's HSPF2: the lowest certified combination, your AHRI figure, or your seasonal COP as an HSPF2 equivalent. Blank for resistance heat.
- H04 New Annual Total Cost
-
Unit $/yr
About this output
Heat pump: Energy cost plus upkeep in year 1.
- H04 New Model Card
-
No unit declared
About this output
Heat pump: The system as the calculator reads it: the resistance heat's yearly kWh, or the heat pump's model, HSPF2, capacities and record.
- H04 NPV Replace Now
-
Unit $
About this output
Present value of keeping minus that of replacing now; positive means replacing now costs less.
- H04 New Seasonal COP Used
-
Unit W/W
About this output
Heat pump: The seasonal coefficient of performance in the sums: 1.0 for resistance heat; for the heat pump your COP, or HSPF2 x 1000 / 3,412.
- H04 Net Initial Cost
-
Unit $
About this output
Installed price, sales tax and extra work, less incentives, plus removal, less the old system's sale value.
- H04 Load Basis Note
-
No unit declared
About this output
How the heating load is worked out: from your heating kWh, with resistance heat delivering all of it as heat.
- H04 New Annual Energy Cost
-
Unit $/yr
About this output
Heat pump: Electricity cost in year 1.
- H04 New Annual KWh
-
Unit kWh/yr
About this output
Heat pump: All electricity in the comparison (heating only in this app).
- H04 New Annual Heating KWh
-
Unit kWh/yr
About this output
Heat pump: Electricity used to heat: the resistance heat, or the heat pump and any electric backup.
LogicCommons is in beta. If a result, label, or reference looks wrong, tell us here; we read every message.
What it is
This calculator weighs keeping your electric resistance heat against replacing it with a heat pump. Enter the electricity you use for heating in a year, pick the new heat pump from the ENERGY STAR list or enter its HSPF2, and choose whether to keep your old heaters as backup. It works out the heat your home needs, each system's yearly electricity use and cost, the yearly saving, the net cost of the heat pump, the simple and discounted payback, and the cost over the years you choose of keeping the old system, replacing it now, or replacing it when it wears out.
Equipment and climate figures come from federal sources only: ENERGY STAR (EPA), DOE standards and test procedures, NOAA climate normals and EIA electricity prices. You set the installed price; the opening example and each worked example carry a round illustrative price, labelled as such.
Methodology
Purpose and model boundary
This calculator compares two ways to heat a home with electricity: keep your electric resistance heat (baseboards, wall heaters or an electric furnace), or replace it with a heat pump. It turns the electricity you use for heating into the heat your home received, works out the electricity a heat pump needs to deliver the same heat, prices both at your electricity price, and sets the yearly saving against what the heat pump costs installed. Over the number of years you choose, it compares keeping the old system, replacing it now and, when you say how many years the old system has left, replacing it when it wears out.
Every figure on this page is computed by the spreadsheet; the page adds nothing to it. It covers the running cost of space heating and the purchase cost only. Cooling from the new heat pump is not credited, and adding ducts or ductless units is not modelled.
Inputs and units
- Your heating electricity: the electricity you use for heating in a year, in kWh. From your bills, take the winter months' use minus your typical use in months with no heating.
- The new heat pump: choose its type (ducted split, ductless mini or multi-split, or single package), then the model from that type's ENERGY STAR list, where each entry reads "Brand | Outdoor model"; or enter the HSPF2 from its AHRI certificate. You may also enter your contractor's seasonal COP, from 1.00 to 6.00, which then replaces the rating.
- Backup heat: none beyond the rating, or keeping the existing resistance heaters as backup, with the share of the year's heat they supply, from 0 to 1.
- Price: the state, which sets the default electricity price, and your own electricity price in dollars per kWh (0.01 to 2.00), optional.
- Purchase and finance: the installed price of the heat pump, which is always yours to set; extra work such as permits, electrical or duct work; sales tax; verified incentives; removal; the old system's sale value; yearly upkeep of each system; the years the old system has left; the new system's expected life; the yearly change in electricity prices; the discount rate; and the years to compare.
Heating and cooling needs are in million Btu (MMBtu) a year of heat delivered or removed. Electricity is in kWh, fuel in US gallons or therms, efficiency ratings in Btu per watt-hour (CEER, SEER2, HSPF2) or as a fraction (AFUE), and money in dollars.
Governing relationships
- Heat delivered by the old system = heating kWh x 3,412 Btu per kWh: resistance heat turns all of its electricity into heat in the home.
- Heat-pump electricity = heat needed / (seasonal COP x 3,412 Btu per kWh). The seasonal COP is HSPF2 x 1000 / 3,412 unless you enter your own, so HSPF2 and COP give the same kWh for the same heat.
- Backup heat: HSPF2 already includes the electric resistance heat a heat pump needs in DOE's moderate rating climate (Region IV), so the backup share is extra heat beyond that, supplied by your resistance heaters at 3,412 Btu per kWh.
- Yearly cost = electricity x electricity price + upkeep. The yearly saving is the old cost minus the new cost.
- Payback and present value follow the rules shared with the other replacement calculators: a simple payback only when the yearly saving is positive, and the costs of keeping, replacing now and replacing at the end of life discounted over the years you compare, with nothing counted twice.
Calculation sequence
The spreadsheet first checks the inputs and finds the heat pump's rating and the electricity price. It turns your heating electricity into the heat your home needed, reduces each system to the electricity it uses per million Btu of heat, and from those computes the yearly electricity, costs and saving; the purchase cost, the paybacks, the present values and the year-by-year cash flow follow. The sensitivity table uses the same per-MMBtu figures, so it cannot disagree with the main result. Consistency checks, including that your heating electricity is reproduced from the computed heat and that the discounted cash flow reaches the same net present value as the closed-form formula, run before the status is returned.
Outputs and interpretation
For each system the results show the heat it delivers, the efficiency used, the yearly electricity and the yearly energy and total cost; then the yearly saving in dollars and in kWh, the net cost of the heat pump, the simple and discounted payback, and the cost of each path.
The cash-flow table shows each year of the years compared: the cost of each path, the net benefit of replacing now, and its cumulative, discounted and cumulative discounted values. The sensitivity table shows the yearly saving with the heat need scaled by 0.50, 0.75, 1.00, 1.25 and 1.50, at the same multiples of the electricity price used.
A model card beside the heat-pump pick shows the range of its ratings across the indoor units it is certified with, whether ENERGY STAR lists it as cold-climate, and its heating capacity. The calculator uses the lowest SEER2 and HSPF2 among those pairings, so it does not credit a better pairing than the one you may buy.
The first chart, “Cumulative net benefit of replacing now, by year”, shows Undiscounted and Discounted by year. The second chart, “Cost over the years compared”, shows Total and Present value by option. The third chart, “Running cost in year 1”, shows Heating electricity, Fuel (none) and Auxiliary electricity and upkeep by system, stacked.
Validation and status logic
The workbook returns one status, chosen in this order: NOT VALID, then CHECK, then OK.
- NOT VALID names the first problem: a heat-pump choice that is not one of its options, a listed model that is not in its list or does not match the type chosen, or a manual HSPF2 missing or outside 5 to 20; a heating electricity figure missing or outside its limits; a backup choice that is not one of its options, or a backup share outside 0 to 1; a seasonal COP outside 1.00 to 6.00; no electricity price, or your own outside 0.01 to 2.00 dollars per kWh; a missing installed price, or one outside its limits; a money amount, the years compared, the price change, the discount rate or a life in years outside its limits.
NOT VALIDis a refusal, not a numeric answer: every figure reads zero and is withheld. - CHECK accompanies a computed result that needs the stated review: a cold state (6,000 heating degree days or more), a heat pump ENERGY STAR does not list as cold-climate, and no backup heat beyond the rating: the HSPF2 rating assumes a moderate climate, so real seasonal efficiency will be lower; with no backup heat, the heat pump's capacity at your coldest month's average temperature is below that month's average heating load, so you may need a larger model, more units or backup heat; a heating electricity figure of zero; no yearly saving, so there is no payback; the old system's remaining life is shorter than the years compared, so read the end-of-life comparison.
- OK otherwise.
Assumptions and limitations
- A heat pump never uses more electricity than resistance heat for the same heat, so the energy saving is never negative. A result with no saving comes from the yearly upkeep you enter for the heat pump, or from your own prices; one worked example shows this with an illustrative service plan.
- Your heating year is taken as a typical year, and your heating electricity is your estimate from your bills. The calculator does not adjust it for a mild or a harsh winter.
- Heating only. Cooling from the new heat pump is not credited; if it also replaces an air conditioner, the cooling side belongs to the heat pump upgrade or central air conditioner calculators. Adding ducts or ductless units is not modelled.
- Inputs with no federal source are your assumptions: the installed price and any backup share beyond the rating. Resistance heat is taken to deliver all its electricity as heat, a design value. The cold-state threshold of 6,000 heating degree days is a design choice that only sets a warning.
- The size check is lenient by design. A true design load needs a design temperature, and no federal table in this calculator gives one per state. So the check compares the heat pump's capacity at the coldest month's mean temperature, read between its rated capacities at 47 °F and 5 °F, with that month's average heating load, worked out from your own heat use and NOAA's monthly degree-day normals. It warns only when the heat pump cannot meet even that average load and no backup heat is chosen.
- Alaska, Hawaii and DC. NOAA publishes no statewide degree-day normals for any of the three. DC uses Maryland's figures; Alaska and Hawaii each use one NOAA station normal, at the Anchorage and Honolulu airports, labelled as a single station. No figure in this calculator depends on degree days: only the cold-state and size checks read them, and a check is not evaluated where its figures are missing.
- Prices. The installed price of the heat pump is always your input; the workbook holds no price table. The opening example and each worked example carry a round illustrative price so that they compute, with the note: "Illustrative price for this example, not a quote or a current price. Prices vary: check current prices online or enter your own. Get a contractor quote."
- The default electricity price is a state average. Your own price from your bill overrides it.
Data and vintage
- Heat pumps: the ENERGY STAR certified air-source heat pump list (EPA), current certifications, one entry per outdoor unit sold in the US, each with the lowest SEER2 and HSPF2 among its certified indoor-unit pairings.
- Climate: NOAA NCEI statewide heating degree-day normals for 1991-2020 (nClimDiv), with the monthly normals for the size check; the US figure covers the 48 contiguous states. NOAA calls these long-term averages rather than official normals, and its notes state neither the base temperature nor the weighting.
- Default price: EIA final 2025 average residential electricity prices by state (Form EIA-861).
- Conversion: 3,412 Btu per kWh, EIA's sample conversion factor.
Worked examples and prices
Prices are not part of the reference data: the price of the new unit is an input you set. The opening example and the five worked examples each use an illustrative price for the new unit, so that the example computes, and each says so: “Illustrative price for this example, not a quote or a current price. Prices vary: check current prices online or enter your own.”
Restrictions and non-computing states
The calculator enforces its numeric and choice limits before it accepts a result. A listed model that is not in its list or does not match the type chosen, a rating or quantity outside its limits, a missing installed price, and a missing electricity or fuel price where no default exists are refused by the workbook.
Errors and warnings
A request rejected by the page's input limits is not a computed result. A transport or service failure, a timeout or a cancelled run cannot establish a fresh workbook answer, and the last result stays on the page marked as out of date. Check your equipment's nameplate or AHRI certificate and your own bills before relying on a result for a purchase, and get a contractor quote for the installed price.
References
Sources and further reading
The calculator reads its model lists, its federal minimum ratings, its climate figures and its default energy prices from reviewed reference tables inside the workbook, with their version shown in the result details. Every table comes from a US federal source. The sources below publish the data and the rules the model applies. They do not endorse this calculator.
- ENERGY STAR data portal catalog (EPA) lists the EPA's certified-product datasets, among them the heat pump list used here (retrieved 2026-10-28).
- ENERGY STAR Certified Heat Pumps (EPA) lists certified air-source heat pumps by outdoor and indoor unit, with SEER2, HSPF2, heating capacity at 47 °F and 5 °F, and a cold-climate flag (retrieved 2026-10-28).
- ENERGY STAR air-source heat pumps: information for partners (EPA) links the ENERGY STAR heat pump specification, whose criteria include the cold-climate designation shown on the model card (retrieved 2026-10-28).
- DOE energy conservation standards, 10 CFR 430.32 (eCFR) sets the federal minimum SEER2 and HSPF2 for heat pumps, which are based on DOE's Region IV climate (retrieved 2026-10-28).
- DOE test procedures, 10 CFR 430 subpart B (eCFR) defines HSPF2, the seasonal heating efficiency of a heat pump (retrieved 2026-10-28).
- NOAA NCEI, Climate Divisional Database (nClimDiv) publishes statewide degree-day normals, used here for 1991-2020 (retrieved 2026-10-28).
- NOAA NCEI, U.S. Climate Normals 1991-2020, station files gives the Anchorage and Honolulu airport normals that stand in for Alaska and Hawaii (retrieved 2026-10-28).
- EIA, British thermal units (Btu) gives 3,412 Btu per kWh (retrieved 2026-10-28).
- EIA, Detailed state data (Form EIA-861) gives the average residential electricity price by state, used here for 2025 (retrieved 2026-10-28).
- EIA, Residential Energy Consumption Survey 2020, state data gives typical space-heating electricity per household by state for 2020, mixing heat pumps and resistance heat; it is a rough cross-check for your own figure, not a value in the calculator (retrieved 2026-10-28).
This is an educational estimate of running and purchase costs for the equipment and prices you enter, not a product recommendation or a quote. Ratings are measured under federal test procedures, not in your home.
Frequently asked questions
How do I find the electricity I use for heating?
Why does a heat pump use so much less electricity?
Does the HSPF2 rating hold in a cold winter?
Why is the model's rating the lowest of a range?
Found a problem, or have an idea?
Tell us if a result looks wrong, a label is unclear, or something is missing. We read every message.