Home And Transportation Savings

Heating Oil To Heat Pump Calculator

Compare keeping your heating oil furnace or boiler with switching to a heat pump: yearly heating oil and electricity, running cost, payback, and the cost over the years you choose. Estimates for planning, not financial advice.

Last updated

How to Use the Heating Oil to Heat Pump Calculator: Keep Your Oil Boiler or Switch?

Plays from YouTube. Close the video to keep working on your drawing.

Calculator overview

Inputs and outputs

This summary comes from the calculator's published input and output contract.

Inputs

H01 Old Equipment (required)
About this input

A furnace heats air; a boiler heats water or makes steam. It chooses the federal minimum when you pick the year made.

Default Boiler (hot water) Allowed Furnace (warm air), Boiler (hot water), Boiler (steam)
H01 Old Aux KWh
When omitted Blank
About this input

Electricity the furnace blower, boiler pump and burner use in a year. AFUE leaves it out, so it is added to the old system. Blank counts none, which is conservative.

Unit kWh/yr Default Not set Range 0 to 3000
H01 Old Fuel Qty (required)
About this input

Your heating oil use over a recent year, in gallons, from your delivery records or bills. It is the baseline: the heating load is worked out from it.

Unit gal/yr Default 700 Range 0 to 10000
H01 Old Fixed Charges
When omitted Blank
About this input

The tank rental or delivery contract fee you stop paying if you close the heating oil account. Under dual fuel the account stays open, so it is counted on both sides.

Unit $/yr Default Not set Range 0 to 2000
H01 New Type (required)
About this input

Ducted split (uses ducts), ductless mini or multi-split, or single package. It chooses which model list is shown.

Default Ducted split Allowed Ducted split, Ductless mini/multi-split, Single package
H01 New Source (required)
About this input

Pick a currently certified ENERGY STAR model by its outdoor unit, or type the HSPF2 from the AHRI certificate your contractor gives you.

Default Model from current ENERGY STAR list Allowed Model from current ENERGY STAR list, Manual entry (AHRI certificate)
H01 Old AFUE Source (required)
About this input

The AFUE from the nameplate or the yellow EnergyGuide label; or, if you cannot find it, the year made, which uses the federal minimum AFUE for that year.

Default Nameplate AFUE Allowed Nameplate AFUE, Model not found: pick approximate age
H01 Old AFUE (required) Conditional
About this input

Annual fuel utilization efficiency: the share of the heating oil burned that becomes useful heat. A steady-state or combustion efficiency is not AFUE.

Default 0.84 Range 0.4 to 0.99
H01 Sales Tax Rate
When omitted Blank
About this input

Applied to the installed price only.

Default Not set Range 0 to 0.15
H01 Rate Growth (required)
About this input

Applied to electricity and heating oil prices alike. 0% means flat prices.

Default 0.02 Range -0.1 to 0.15
H01 State (required)
About this input

USPS state code, or US for the national average. It sets the default electricity and heating oil prices (state averages, not your tariffs) and the climate used by the two climate checks.

Default US Allowed AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, IA, ID, IL, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WI, WV, WY, US
H01 Space Heat Share (required)
About this input

The part of your heating oil that heats the home. Lower it if heating oil also heats water, cooks or dries clothes. Left blank, all the heating oil is counted as space heating and the status asks you to check it.

Default 1 Range 0.05 to 1
H01 Old Remaining Life
When omitted Blank
About this input

Fills the replace-at-end-of-life comparison. Blank skips it.

Unit years Default Not set Range 0 to 30
H01 Old Maintenance
When omitted Blank
About this input

Service or repairs you expect each year if you keep the heating oil system.

Unit $/yr Default Not set Range 0 to 5000
H01 Old Vintage (required) Conditional
About this input

When the AFUE is not known: the year made. The federal minimum AFUE for that equipment and year is used; your system may be more efficient, so the status says so.

Default Made in 2005 Allowed Made in 1992, Made in 1993, Made in 1994, Made in 1995, Made in 1996, Made in 1997, Made in 1998, Made in 1999, Made in 2000, Made in 2001, Made in 2002, Made in 2003, Made in 2004, Made in 2005, Made in 2006, Made in 2007, Made in 2008, Made in 2009, Made in 2010, Made in 2011, Made in 2012, Made in 2013, Made in 2014, Made in 2015, Made in 2016, Made in 2017, Made in 2018, Made in 2019, Made in 2020, Made in 2021, Made in 2022, Made in 2023, Made in 2024, Made in 2025
H01 Old Sale Value
When omitted Blank
About this input

Money you receive for the old system if you replace it now.

Unit $ Default Not set Range 0 to 5000
H01 New Model Split (required) Conditional
About this input

Brand and outdoor unit model as listed by ENERGY STAR. The lowest HSPF2 of its certified combinations is used.

Default Carrier | D5CURAH36AAK Allowed 1HVAC | ACIQ-12-EHPB, 1HVAC | ACIQ-12-EHPD, 1HVAC | ACIQ-18-EHPD, 1HVAC | ACIQ-18-HPB, 1HVAC | ACIQ-18-HPD, 1HVAC | ACIQ-18ZPL-HP230B, 1HVAC | ACIQ-24-EHPB, 1HVAC | ACIQ-24-EHPD, 1HVAC | ACIQ-24-HP32, 1HVAC | ACIQ-24-HPB, and 4,581 more (the calculator lists them all)
H01 Extra Work
When omitted Blank
About this input

Work beyond the installed price, if your quote lists it separately.

Unit $ Default Not set Range 0 to 50000
H01 Electricity Rate Override
When omitted Blank
About this input

From your bill. Overrides the state average.

Unit $/kWh Default Not set Range 0.01 to 2
H01 Horizon Years (required)
About this input

The comparison period, 1 to 30 whole years.

Unit years Default 15 Range 1 to 30
H01 Fuel Price Override
When omitted Blank
About this input

From your heating oil bill, per gal. Overrides the default for your state.

Unit $/gal Default Not set Range 0.5 to 15
H01 Backup Type (required)
About this input

HSPF2 already includes the backup heat of a moderate climate. Choose a backup only for extra heat in a colder climate: electric strips, or keeping the heating oil system for the coldest days (dual fuel).

Default None beyond the rating Allowed None beyond the rating, Electric resistance, Keep the existing oil system (dual fuel)
H01 Backup Share (required) Conditional
About this input

The extra share of the yearly heat the backup supplies. Read only when a backup is chosen.

Default 0.1 Range 0 to 1
H01 Disposal
When omitted Blank
About this input

Removal or capping charge, if not in the quote.

Unit $ Default Not set Range 0 to 5000
H01 Discount Rate (required)
About this input

The yearly return you could earn on the money instead. 0% means no discounting.

Default 0.03 Range 0 to 0.2
H01 New Manual HSPF2 (required) Conditional
About this input

The heating seasonal performance factor (HSPF2, 2023 test basis) of the matched system. Never an older HSPF figure.

Unit Btu/Wh Default 8 Range 5 to 20
H01 New Maintenance
When omitted Blank
About this input

Service you expect each year for the heat pump.

Unit $/yr Default Not set Range 0 to 5000
H01 New Model Pkg (required) Conditional
About this input

Brand and model as listed by ENERGY STAR (single package). The lowest HSPF2 of its certified combinations is used.

Default 1HVAC | ACIQ-PHH1748000K000V Allowed 1HVAC | ACIQ-PHH1748000K000V, 1HVAC | ACIQ-PHH1760000K000V, AC PRO | AK-H04TC/NAA-T(U), AC PRO | AK-H05TC/NAA-T(U), AC PRO | PKHP-X-024VBC, AC PRO | PKHP-X-036VBC, AC PRO | PKHP-X-048VBC, AC PRO | PKHP-X-060VBC, ACIQ | ACIQ-PHH1748000K000V, ACIQ | ACIQ-PHH1760000K000V, and 820 more (the calculator lists them all)
H01 New Model Mini (required) Conditional
About this input

Brand and outdoor unit model as listed by ENERGY STAR (ductless mini and multi-split). The lowest HSPF2 of its certified combinations is used.

Default 1HVAC | ACIQ-06ZPL-HP230B Allowed 1HVAC | ACIQ-06ZPL-HP230B, 1HVAC | ACIQ-06ZPL-HP230C, 1HVAC | ACIQ-09Z-HP115B, 1HVAC | ACIQ-09Z-HP115C, 1HVAC | ACIQ-09Z-HP230C, 1HVAC | ACIQ-09ZPL-HP230B, 1HVAC | ACIQ-09ZPL-HP230C, 1HVAC | ACIQ-09ZS-HP115C, 1HVAC | ACIQ-09ZS-HP230C, 1HVAC | ACIQ-12ZPL-HP230B, and 7,091 more (the calculator lists them all)
H01 Incentives
When omitted Blank
About this input

Only incentives you have confirmed you qualify for.

Unit $ Default Not set Range 0 to 5000
H01 HP Seasonal COP Override
When omitted Blank
About this input

A seasonal coefficient of performance for your climate, if your contractor states one. It replaces the HSPF2 rating, which assumes a moderate climate.

Unit W/W Default Not set Range 1 to 6
H01 New Installed Price (required)
About this input

The installed price of the heat pump job, from your contractor's quote. The calculator never looks up a price. Illustrative price for this example, not a quote or a current price. Prices vary: check current prices online or enter your own. Get a contractor quote.

Unit $ Default 12000 Range 1 to 60000
H01 New Expected Life
When omitted Blank
About this input

Used only for the value left in the heat pump at the end of the period (straight line). Blank counts no value left: no lifetime is sourced for this app.

Unit years Default Not set Range 1 to 40

Outputs

H01 Old Seasonal COP Used
About this output

Old heating oil system: The seasonal coefficient of performance in the sums: your COP, or HSPF2 x 1000 / 3,412. Blank for the heating oil system.

Unit W/W
H01 Old Model Card
About this output

Old heating oil system: The system as the calculator reads it: the heating oil system's equipment and AFUE, or the heat pump's model, HSPF2, capacities and record.

No unit declared
H01 Old Eff Heating Used
About this output

Old heating oil system: The heat pump's HSPF2: the lowest certified combination, your AHRI figure, or your seasonal COP as an HSPF2 equivalent. Blank for the heating oil system.

Unit Btu/Wh
H01 PV Replace Now
About this output

Present value of replacing now at the discount rate.

Unit $
H01 PV Replace End Of Life
About this output

Present value of replacing when the heating oil system fails. Blank when not evaluated.

Unit $
H01 PV Keep
About this output

Present value of keeping the heating oil system at the discount rate.

Unit $
H01 Old Annual Fuel
About this output

Old heating oil system: Heating oil burned for space heating: by the old system, or by the kept system under dual fuel.

Unit gal/yr
H01 Old Annual Energy Cost
About this output

Old heating oil system: Electricity, heating oil and fixed heating oil charges in year 1.

Unit $/yr
H01 Old AFUE Used
About this output

The AFUE in the sums: the nameplate figure, or the federal minimum for the year made.

No unit declared
H01 Old Annual Total Cost
About this output

Old heating oil system: Energy cost plus upkeep in year 1.

Unit $/yr
H01 Old Annual KWh
About this output

Old heating oil system: All electricity in the comparison: heating, plus the heating oil system's auxiliary electricity.

Unit kWh/yr
H01 Old Annual Heating KWh
About this output

Old heating oil system: Electricity used to heat: the heat pump and any electric backup. Zero for the heating oil system.

Unit kWh/yr
H01 Total Keep
About this output

Running cost of keeping the heating oil system over the years compared, without discounting.

Unit $
H01 Status Code
About this output

The deciding reason of the status line as a short code, OK when nothing applies.

No unit declared
H01 Simple Payback Years
About this output

Net initial cost divided by the money saved in year 1. Blank when nothing is saved or the price is missing.

Unit years
Model Status
About this output

OK, CHECK with a reason to read, or NOT VALID with what to fix.

No unit declared
H01 Total Replace Now
About this output

Net initial cost plus the heat pump's running cost over the years compared, less any value left at the end, without discounting.

Unit $
H01 Total Replace End Of Life
About this output

Keep the heating oil system until it fails, then install the heat pump at today's price. Blank when no remaining life below the period is given.

Unit $
H01 Self Check
About this output

Whether the model's internal consistency checks hold.

No unit declared
H01 Replace Now Verdict
About this output

The comparison of replacing now with keeping, in words.

No unit declared
H01 Rating Note
About this output

Which heat pump rating is used: the lowest certified combination, your AHRI figure, or your seasonal COP.

No unit declared
H01 Simple Payback Text
About this output

The simple payback in words: the years, no payback, or a missing price.

No unit declared
H01 Sensitivity Savings
About this output

Money saved in year 1 for 50% to 150% of the heating load (rows) and 50% to 150% of the electricity price used (columns).

No unit declared
H01 Sensitivity Fuel
About this output

Money saved in year 1 for 50% to 150% of the heating oil price used (rows) and 50% to 150% of the electricity price used (columns), at your heating load. Heating oil against electricity price decides a fuel switch.

No unit declared
H01 NPV Replace Now
About this output

Present value of keeping minus that of replacing now; positive means replacing now costs less.

Unit $
H01 Electricity Rate Note
About this output

Where the electricity price comes from: the EIA state average and its year, or your own price.

No unit declared
H01 Discounted Payback Year
About this output

The first year in which the cumulative discounted net benefit of replacing now reaches zero. Blank when it does not within the years compared.

Unit year
H01 Discounted Payback Text
About this output

The discounted payback in words.

No unit declared
H01 Fuel Rate Note
About this output

Where the heating oil price comes from: the EIA state average, its period and level, or your own price.

No unit declared
H01 End Of Life Verdict
About this output

The comparison of replacing now with waiting until the heating oil system fails, in words.

No unit declared
H01 Electricity Rate Used
About this output

The electricity price in the sums: your own, or the state average.

Unit $/kWh
H01 Annual Savings USD
About this output

Old minus new running cost in year 1; negative means the heat pump costs more to run.

Unit $/yr
H01 Annual KWh Change
About this output

Old minus new electricity a year. It is normally negative: the heat pump uses electricity in place of heating oil.

Unit kWh/yr
H01 Annual Fuel Savings
About this output

Old minus new heating oil a year for space heating.

Unit gal/yr
H01 Data Vintage Note
About this output

The sources and their dates.

No unit declared
H01 Climate HDD Used
About this output

Your state's yearly heating degree day normal (NOAA 1991-2020), used only by the two climate checks.

Unit deg F-day
H01 Cash Flow
About this output

Year-by-year costs of keeping, replacing now and replacing at end of life, the net benefit of replacing now, and its cumulative and discounted values. Rows past the years compared are blank.

No unit declared
H01 New Annual Total Cost
About this output

Heat pump: Energy cost plus upkeep in year 1.

Unit $/yr
H01 New Annual KWh
About this output

Heat pump: All electricity in the comparison: heating, plus the heating oil system's auxiliary electricity.

Unit kWh/yr
H01 New Annual Heating KWh
About this output

Heat pump: Electricity used to heat: the heat pump and any electric backup. Zero for the heating oil system.

Unit kWh/yr
H01 New Seasonal COP Used
About this output

Heat pump: The seasonal coefficient of performance in the sums: your COP, or HSPF2 x 1000 / 3,412. Blank for the heating oil system.

Unit W/W
H01 New Model Card
About this output

Heat pump: The system as the calculator reads it: the heating oil system's equipment and AFUE, or the heat pump's model, HSPF2, capacities and record.

No unit declared
H01 New Eff Heating Used
About this output

Heat pump: The heat pump's HSPF2: the lowest certified combination, your AHRI figure, or your seasonal COP as an HSPF2 equivalent. Blank for the heating oil system.

Unit Btu/Wh
H01 Load Basis Note
About this output

How the heating load is worked out: from your heating oil use, the space-heating share and the old AFUE.

No unit declared
H01 Heating Load MMBtu
About this output

Heat the home needs in a year, worked out from your heating oil use, the space-heating share and the old AFUE. Old and new deliver the same heat.

Unit MMBtu/yr
H01 Fuel Rate Used
About this output

The heating oil price in the sums: your own, or the state average.

Unit $/gal
H01 New Annual Fuel
About this output

Heat pump: Heating oil burned for space heating: by the old system, or by the kept system under dual fuel.

Unit gal/yr
H01 New Annual Energy Cost
About this output

Heat pump: Electricity, heating oil and fixed heating oil charges in year 1.

Unit $/yr
H01 Net Initial Cost
About this output

Installed price, sales tax and extra work, less incentives, plus removal, less the old system's sale value.

Unit $
This page is provided by LogicCommons for informational purposes only. Results are model outputs computed from the inputs you supply and are not financial, investment, tax, accounting, or legal advice, and no advisory relationship is created. Verify all inputs and results independently before relying on them in any decision.

LogicCommons is in beta. If a result, label, or reference looks wrong, tell us here; we read every message.

What it is

This calculator weighs keeping your oil-fired furnace or boiler against replacing it with an electric heat pump. Enter the heating oil you use in a year and the old system's AFUE, or the year it was made; pick the new heat pump from the ENERGY STAR list or enter its HSPF2; and choose any backup heat. It works out the heat your home needs, each system's yearly energy use and cost, the yearly saving, the net cost of the heat pump, the simple and discounted payback, and the cost over the years you choose of keeping the old system, replacing it now, or replacing it when it wears out.

Equipment and climate figures come from federal sources only: ENERGY STAR (EPA), DOE efficiency standards and test procedures, NOAA climate normals and EIA energy prices. You set the installed price; the opening example and each worked example carry a round illustrative price, labelled as such.

Methodology

Purpose and model boundary

This calculator compares two ways to heat a home: keep the oil-fired furnace or boiler you have, or replace it with an electric heat pump. It turns your yearly heating oil use into the heat your home received, works out the electricity a heat pump needs to deliver the same heat, prices both at your oil and electricity prices, and sets the yearly saving against what the heat pump costs installed. Over the number of years you choose, it compares keeping the old system, replacing it now and, when you say how many years the old system has left, replacing it when it wears out.

Every figure on this page is computed by the spreadsheet; the page adds nothing to it. It covers the running cost of space heating and the purchase cost only. Cooling from the new heat pump is not credited, and a change of distribution system (from a boiler to ducts, or to ductless units) is not modelled.

Inputs and units

  • Your oil use: the heating oil you use in a year, in US gallons, from your delivery records (0 to 10,000), and the share of it that heats the house. A blank share counts all of it as space heating; if the oil also heats your water, lower the share.
  • The old furnace or boiler: its type (furnace, hot-water boiler or steam boiler) and its AFUE, the annual fuel utilization efficiency printed on its nameplate or yellow EnergyGuide label, from 0.40 to 0.99. A steady-state or combustion efficiency is not an AFUE. If the AFUE is unknown, pick the year the system was made and the calculator uses the federal minimum AFUE for that year.
  • Optional extras for the old system: the electricity its burner, blower or pump uses in a year, which AFUE leaves out (blank counts none), and fixed charges you would stop paying, such as a tank rental.
  • The new heat pump: choose its type (ducted split, ductless mini or multi-split, or single package), then the model from that type's ENERGY STAR list, where each entry reads "Brand | Outdoor model"; or enter the HSPF2 from its AHRI certificate. You may also enter your contractor's seasonal COP, from 1.00 to 6.00, which then replaces the rating.
  • Backup heat: none beyond the rating, electric resistance, or keeping the existing oil system for the coldest days (dual fuel), with the share of the year's heat the backup supplies, from 0 to 1.
  • Prices: the state, which sets the default electricity and heating oil prices; your own electricity price in dollars per kWh (0.01 to 2.00) and your own oil price in dollars per gallon (0.50 to 15.00), each optional.
  • Purchase and finance: the installed price of the heat pump, which is always yours to set; extra work such as permits, electrical or duct work; sales tax; verified incentives; removal; the old system's sale value; yearly upkeep of each system; the years the old system has left; the new system's expected life; the yearly change in energy prices; the discount rate; and the years to compare.

Heating and cooling needs are in million Btu (MMBtu) a year of heat delivered or removed. Electricity is in kWh, fuel in US gallons or therms, efficiency ratings in Btu per watt-hour (CEER, SEER2, HSPF2) or as a fraction (AFUE), and money in dollars.

Governing relationships

  • Heat delivered by the old system = yearly oil x space-heat share x 138,500 Btu per gallon x AFUE.
  • Heat-pump electricity = heat needed / (seasonal COP x 3,412 Btu per kWh). The seasonal COP is HSPF2 x 1000 / 3,412 unless you enter your own, so HSPF2 and COP give the same kWh for the same heat.
  • Backup heat: HSPF2 already includes the electric resistance heat a heat pump needs in DOE's moderate rating climate (Region IV), so the backup share is extra heat beyond that. Electric backup turns each kWh into 3,412 Btu of heat; dual-fuel backup burns oil at the old system's AFUE.
  • Yearly cost = electricity x electricity price + oil x oil price + upkeep, plus, for the old system, the fixed charges the switch avoids. With dual-fuel backup the oil system stays, so those charges count for the new system too. The yearly saving is the old cost minus the new cost.
  • Payback and present value follow the rules shared with the other replacement calculators: a simple payback only when the yearly saving is positive, and the costs of keeping, replacing now and replacing at the end of life discounted over the years you compare, with nothing counted twice.

Calculation sequence

The spreadsheet first checks the inputs and finds the old system's AFUE, the heat pump's rating and the prices. It turns your oil use into the heat your home needed, reduces each system to the energy it uses per million Btu of heat, and from those computes the yearly electricity, oil, costs and saving; the purchase cost, the paybacks, the present values and the year-by-year cash flow follow. The sensitivity tables use the same per-MMBtu figures, so they cannot disagree with the main result. Consistency checks, including that your oil use is reproduced from the computed heat and that the discounted cash flow reaches the same net present value as the closed-form formula, run before the status is returned.

Outputs and interpretation

For each system the results show the heat it delivers, the efficiency used, the yearly electricity and oil, and the yearly energy and total cost; then the yearly saving in dollars, the change in electricity use, the oil saved, the net cost of the heat pump, the simple and discounted payback, and the cost of each path. Switching to a heat pump normally raises electricity use while removing oil use: the change in electricity is shown as old minus new, so it is usually negative, with a sentence that says so. A note states where the heat figure came from: your oil use.

The cash-flow table shows each year of the years compared: the cost of each path, the net benefit of replacing now, and its cumulative, discounted and cumulative discounted values. The first sensitivity table shows the yearly saving with the heat need scaled by 0.50, 0.75, 1.00, 1.25 and 1.50, at the same multiples of the electricity price used. The second sensitivity table shows the yearly saving at 0.50 to 1.50 times the oil price used against 0.50 to 1.50 times the electricity price used. The balance of the two prices is what decides whether switching pays.

A model card beside the heat-pump pick shows the range of its ratings across the indoor units it is certified with, whether ENERGY STAR lists it as cold-climate, and its heating capacity. The calculator uses the lowest SEER2 and HSPF2 among those pairings, so it does not credit a better pairing than the one you may buy.

The first chart, “Cumulative net benefit of replacing now, by year”, shows Undiscounted and Discounted by year. The second chart, “Cost over the years compared”, shows Total and Present value by option. The third chart, “Running cost in year 1”, shows Heating electricity, Heating oil and fixed heating oil charges and Auxiliary electricity and upkeep by system, stacked.

Validation and status logic

The workbook returns one status, chosen in this order: NOT VALID, then CHECK, then OK.

  • NOT VALID names the first problem: an old-system choice that is not one of its options; no federal minimum AFUE on file for that equipment and year made, in which case use the nameplate AFUE; an AFUE missing or outside 0.40 to 0.99; a heat-pump choice that is not one of its options, a listed model that is not in its list or does not match the type chosen, or a manual HSPF2 missing or outside 5 to 20; a yearly oil use missing or outside 0 to 10,000 gallons, or a space-heat share outside 0.05 to 1; a backup choice that is not one of its options, or a backup share outside 0 to 1; a seasonal COP outside 1.00 to 6.00; no electricity price, or your own outside 0.01 to 2.00 dollars per kWh; no oil price at the state, regional or US level and none of your own, or your own outside its limits; a missing installed price, or one outside its limits; a money amount, the years compared, the price change, the discount rate or a life in years outside its limits. NOT VALID is a refusal, not a numeric answer: every figure reads zero and is withheld.
  • CHECK accompanies a computed result that needs the stated review: the AFUE is the federal minimum for the year made; the old system may be more efficient, so the saving may be overstated; a cold state (6,000 heating degree days or more), a heat pump ENERGY STAR does not list as cold-climate, and no backup heat beyond the rating: the HSPF2 rating assumes a moderate climate, so real seasonal efficiency will be lower; with no backup heat, the heat pump's capacity at your coldest month's average temperature is below that month's average heating load, so you may need a larger model, more units or backup heat; the space-heat share is blank, so all the oil is counted as space heating; a yearly oil use of zero; no yearly saving: the heat pump costs as much or more to run, so there is no payback; the old system's remaining life is shorter than the years compared, so read the end-of-life comparison.
  • OK otherwise.

Assumptions and limitations

  • Your oil year is taken as a typical year. The calculator does not adjust your deliveries for a mild or a harsh winter; use a full year of deliveries.
  • Heating only, like for like. Cooling from the new heat pump is not credited; if it also replaces an air conditioner, the cooling side belongs to the heat pump upgrade or central air conditioner calculators. AFUE and HSPF2 both leave out duct and pipe losses, so the comparison is like for like; a change from a boiler to ducts or to ductless units is not modelled.
  • A federal minimum is a floor, not a measurement. A system described by the year it was made may be more efficient than the minimum, so the saving may be overstated. Where the minimum changed during a year, the newer, higher minimum is used, which keeps the saving on the low side. Wear with age is not modelled.
  • Inputs with no federal source are your assumptions: the installed price, the share of oil used for space heating, any backup share beyond the rating, the old system's auxiliary electricity and the fixed charges avoided. The cold-state threshold of 6,000 heating degree days is a design choice that only sets a warning.
  • The size check is lenient by design. A true design load needs a design temperature, and no federal table in this calculator gives one per state. So the check compares the heat pump's capacity at the coldest month's mean temperature, read between its rated capacities at 47 °F and 5 °F, with that month's average heating load, worked out from your own heat use and NOAA's monthly degree-day normals. It warns only when the heat pump cannot meet even that average load and no backup heat is chosen.
  • Alaska, Hawaii and DC. NOAA publishes no statewide degree-day normals for any of the three. DC uses Maryland's figures; Alaska and Hawaii each use one NOAA station normal, at the Anchorage and Honolulu airports, labelled as a single station. No figure in this calculator depends on degree days: only the cold-state and size checks read them, and a check is not evaluated where its figures are missing.
  • Prices. The installed price of the heat pump is always your input; the workbook holds no price table. The opening example and each worked example carry a round illustrative price so that they compute, with the note: "Illustrative price for this example, not a quote or a current price. Prices vary: check current prices online or enter your own. Get a contractor quote."
  • Default oil prices are partial and exclude taxes. EIA publishes weekly residential heating oil prices for 23 states, only in the heating season; the default is their average over the last complete season (October 2025 to March 2026), with the regional or US figure elsewhere, and the note says which. EIA's prices exclude taxes, so your delivered price is higher: enter your own for a closer result.

Data and vintage

  • Heat pumps: the ENERGY STAR certified air-source heat pump list (EPA), current certifications, one entry per outdoor unit sold in the US, each with the lowest SEER2 and HSPF2 among its certified indoor-unit pairings.
  • Federal minimum AFUE by year made: DOE energy conservation standards (10 CFR 430.32), with earlier editions of the Code of Federal Regulations (1997 and 2012) for the years before the current standard.
  • Climate: NOAA NCEI statewide heating degree-day normals for 1991-2020 (nClimDiv), with the monthly normals for the size check; the US figure covers the 48 contiguous states. NOAA calls these long-term averages rather than official normals, and its notes state neither the base temperature nor the weighting.
  • Default prices: EIA final 2025 average residential electricity prices by state (Form EIA-861), and EIA weekly residential heating oil prices averaged over the 2025-26 heating season.
  • Heat content: 138,500 Btu per gallon of heating oil and 3,412 Btu per kWh, EIA's sample conversion factors.

Worked examples and prices

Prices are not part of the reference data: the price of the new unit is an input you set. The opening example and the five worked examples each use an illustrative price for the new unit, so that the example computes, and each says so: “Illustrative price for this example, not a quote or a current price. Prices vary: check current prices online or enter your own.”

Restrictions and non-computing states

The calculator enforces its numeric and choice limits before it accepts a result. A listed model that is not in its list or does not match the type chosen, a rating or quantity outside its limits, a missing installed price, and a missing electricity or fuel price where no default exists are refused by the workbook.

Errors and warnings

A request rejected by the page's input limits is not a computed result. A transport or service failure, a timeout or a cancelled run cannot establish a fresh workbook answer, and the last result stays on the page marked as out of date. Check your equipment's nameplate or AHRI certificate and your own bills before relying on a result for a purchase, and get a contractor quote for the installed price.

References

Sources and further reading

The calculator reads its model lists, its federal minimum ratings, its climate figures and its default energy prices from reviewed reference tables inside the workbook, with their version shown in the result details. Every table comes from a US federal source. The sources below publish the data and the rules the model applies. They do not endorse this calculator.

This is an educational estimate of running and purchase costs for the equipment and prices you enter, not a product recommendation or a quote. Ratings are measured under federal test procedures, not in your home.

Frequently asked questions

Why does the calculator ask for my oil use instead of the size of my house?
Your own deliveries are the most direct measure of the heat your home needs. The calculator turns the oil you used into the heat your home received, using the old system's AFUE, and works out how much electricity a heat pump needs to deliver the same heat.
What is AFUE, and where do I find it?
AFUE, the annual fuel utilization efficiency, is the share of the fuel's energy a furnace or boiler delivers as useful heat, measured under the DOE test procedure. It is printed on the nameplate or the yellow EnergyGuide label. A steady-state or combustion efficiency is a different figure. If you cannot find the AFUE, pick the year the system was made: the calculator then uses the federal minimum for that year and warns that the saving may be overstated.
My state has no oil price. What does the calculator use?
EIA publishes weekly residential heating oil prices for 23 states. Elsewhere the calculator uses the regional average, or the US average, and the price note says which. EIA's prices exclude taxes, so enter your own price per gallon for a result that matches your deliveries.
Does the HSPF2 rating hold in a cold winter?
HSPF2 is measured for DOE's moderate rating climate (Region IV) and already includes the electric backup heat needed there. In a colder state real seasonal efficiency is lower: choose a model ENERGY STAR lists as cold-climate, enter your contractor's seasonal COP, or add a backup share. The calculator warns when your state is cold and none of these is set.
Why is the model's rating the lowest of a range?
A split heat pump's rating belongs to the outdoor unit paired with a particular indoor unit, and ENERGY STAR certifies many pairings. The list holds one entry per outdoor unit with the lowest SEER2 and HSPF2 among its pairings, and the model card shows the range. If your contractor quotes a specific pairing, enter its HSPF2 from the AHRI certificate instead.
What if I keep the oil boiler as a backup?
Choose dual-fuel backup and the share of the year's heat it supplies. That share burns oil at the old system's AFUE, and because the oil system stays, any fixed charges you entered count for the new system too.
Results are informational and not professional advice. See our Terms of Use. Powered by SpreadsheetWeb · About · Privacy · Terms